HOW TO REPLACE SANYO PLV Z3 LAMP
Turn off the projector and disconnect the AC plug. Allow the projector to cool for at least 45 minutes. Turn over the projector. Loosen the screw with a screwdriver and remove the lamp cover. Loosen two screws of the lamp with a screwdriver and pull out the lamp by grasping the handle. Replace the lamp with a new one and tighten the two screws back into position. Make sure that the lamp is set properly. Replace tha lamp cover and tighten the screw. Connect the AC power cord to the projector and turn on the projector. Reset the lamp replace counter. Turn the projector on, press the MENU botton, and the OnScreen Menu will appear. Select the Setting Menu with the Point Up/Down button and press the Point Right button to enter the sub-menu. Select the Lamp counter reset item and then press the SELECT button. The message Lamp replace counter reset is displayed. Choose YES and then press the SELECT button. Another confirmation dialog box appears and choose YES to reset the LAMP replace counter |
|